mandag 7. november 2011

EMC ControlCenter GUI ends Dissolve META with Successful Operation, but no further Operations are then allowed on the dissolved meta members

Error msg in EGS log:

ConfigSession_23 CFGCHG_ACTN_COMMIT / 5 SYMAPI_CFGSTATE_RUNNING / 1 46 45 0 SYMAPI_C_SUCCESS / 0 0 SYMAPI_C_SRVR_SUCCESS / 0 `The service request was successful` 0
ConfigSession_23 SymConfigChangeSessionEnd ( $handle 1 NULL )
ConfigSession_23 Success
ConfigSession_24 2550 Unable to acquire the Symmetrix device lock


Fix
symdev -sid xxx -force -lock release symdev# (or -range symdevstart:symmdevend)
or
stop / start the Symmetrix Agent that did the ECC config change